| Name Strings | |
| cl_khr_icd | |
| Contributors | |
| Ben Ashbaugh | |
| Christopher Cameron | |
| Benedict Gaster | |
| Michael Houston | |
| John Kessenich | |
| Christopher Lamb | |
| Laurent Morichetti | |
| Aftab Munshi | |
| Ofer Rosenberg | |
| IP Status | |
| No known claims. | |
| Version | |
| Version 8, August 8, 2017 | |
| Number | |
| OpenCL Extension #5 | |
| Status | |
| Ratified by the Khronos Promoters, January 29, 2010 | |
| Extension Type | |
| OpenCL platform extension | |
| Dependencies | |
| OpenCL 1.0 is required. | |
| Overview | |
| This extension defines a simple mechanism through which the Khronos | |
| installable client driver loader (ICD Loader) may expose multiple | |
| separate vendor installable client drivers (Vendor ICDs) for | |
| OpenCL. An application written against the ICD Loader will be able to | |
| access all cl_platform_ids exposed by all vendor implementations | |
| with the ICD Loader acting as a demultiplexor. | |
| Inferring Vendors From Function Calls from Arguments | |
| At every OpenCL function call, the ICD Loader infers the Vendor ICD | |
| function to call from the arguments to the function. An object is | |
| said to be ICD compatible if it is of the following structure: | |
| struct _cl_<object> | |
| { | |
| struct _cl_icd_dispatch *dispatch; | |
| // ... remainder of internal data | |
| }; | |
| <object> is one of platform_id, device_id, context, command_queue, | |
| mem, program, kernel, event, or sampler. | |
| The structure _cl_icd_dispatch is a function pointer dispatch | |
| table which is used to direct calls to a particular vendor | |
| implementation. All objects created from ICD compatible objects | |
| must be ICD compatible. | |
| A link to source code which defines the entries in the function | |
| table structure _cl_icd_dispatch is available in the Sample | |
| Code section of this document. The order of the functions in | |
| _cl_icd_dispatch is determined by the ICD Loader's source. The ICD | |
| Loader's source's _cl_icd_dispatch table is to be appended to only. | |
| Functions which do not have an argument from which the vendor | |
| implementation may be inferred are ignored, with the exception | |
| of clGetExtensionFunctionAddress which is described below. | |
| ICD Data | |
| A Vendor ICD is defined by two pieces of data. | |
| The Vendor ICD library specifies a library which contains the | |
| OpenCL entrypoints for the vendor's OpenCL implementation. The | |
| vendor ICD's library file name should include the vendor name, or | |
| a vendor-specific implementation identifier. | |
| The Vendor ICD extension suffix is a short string which specifies | |
| the default suffix for extensions implemented only by that vendor. | |
| See Additions to Chapter 9 for details on the mechanism through | |
| which this is accomplished. The vendor suffix string is optional. | |
| ICD Loader Vendor Enumeration on Windows | |
| To enumerate Vendor ICDs on Windows, the ICD Loader will first | |
| scan for REG_SZ string values in the "Display Adapter" and | |
| "Software Components" HKR registry keys. The exact registry | |
| keys to scan should be obtained via PnP Configuration Manager | |
| APIs, but will look like: | |
| For 64-bit ICDs: | |
| HKLM\SYSTEM\CurrentControlSet\Control\Class\ | |
| {Display Adapter GUID}\{Instance ID}\OpenCLDriverName, or | |
| HKLM\SYSTEM\CurrentControlSet\Control\Class\ | |
| {Software Component GUID}\{Instance ID}\OpenCLDriverName | |
| For 32-bit ICDs: | |
| HKLM\SYSTEM\CurrentControlSet\Control\Class\ | |
| {Display Adapter GUID}\{Instance ID}\OpenCLDriverNameWoW, or | |
| HKLM\SYSTEM\CurrentControlSet\Control\Class\ | |
| {Software Component GUID}\{Instance ID}\OpenCLDriverNameWoW | |
| These registry values contain the path to the Vendor ICD library. | |
| For example, if the registry contains the value: | |
| [HKLM\SYSTEM\CurrentControlSet\Control\Class\{GUID}\{Instance}] | |
| "OpenCLDriverName"="c:\\vendor a\\vndra_ocl.dll" | |
| Then the ICD loader will open the Vendor ICD library: | |
| "c:\vendor a\vndra_ocl.dll" | |
| The ICD Loader will also scan for REG_DWORD values in the registry | |
| key: | |
| HKLM\SOFTWARE\Khronos\OpenCL\Vendors | |
| For each registry value in this key which has data set to 0, the | |
| ICD Loader will open the Vendor ICD library specified by the name | |
| of the registry value. | |
| For example, if the registry contains the value: | |
| [HKLM\SOFTWARE\Khronos\OpenCL\Vendors] | |
| "c:\\vendor a\\vndra_ocl.dll"=dword:00000000 | |
| Then the ICD will open the Vendor ICD library: | |
| "c:\vendor a\vndra_ocl.dll" | |
| ICD Loader Vendor Enumeration on Linux | |
| To enumerate vendor ICDs on Linux, the ICD Loader scans | |
| the files the path /etc/OpenCL/vendors. For each | |
| file in this path, the ICD Loader opens the file as a text | |
| file. The expected format for the file is a single line of | |
| text which specifies the Vendor ICD's library. The ICD | |
| Loader will attempt to open that file as a shared object | |
| using dlopen(). Note that the library specified may be an | |
| absolute path or just a file name. | |
| For example, if the following file exists | |
| /etc/OpenCL/vendors/VendorA.icd | |
| and contains the text | |
| libVendorAOpenCL.so | |
| then the ICD Loader will load the library "libVendorAOpenCL.so" | |
| Adding a Vendor Library | |
| Upon successfully loading a Vendor ICD's library, the | |
| ICD Loader queries the following functions from the library: | |
| clIcdGetPlatformIDsKHR, clGetPlatformInfo, and | |
| clGetExtensionFunctionAddress. If any of these functions | |
| are not present then the ICD Loader will close and ignore | |
| the library. | |
| Next the ICD Loader queries available ICD-enabled | |
| platforms in the library using clIcdGetPlatformIDsKHR. | |
| For each of these platforms, the ICD Loader queries the | |
| platform's extension string to verify that cl_khr_icd is | |
| supported, then queries the platform's Vendor ICD extension | |
| suffix using clGetPlatformInfo with the value | |
| CL_PLATFORM_ICD_SUFFIX_KHR. | |
| If any of these steps fail, the ICD Loader will ignore the | |
| Vendor ICD and continue on to the next. | |
| New Procedures and Functions | |
| cl_int clIcdGetPlatformIDsKHR( | |
| cl_uint num_entries, | |
| cl_platform_id *platforms, | |
| cl_uint *num_platforms); | |
| New Tokens | |
| Accepted as <param_name> to the function clGetPlatformInfo | |
| CL_PLATFORM_ICD_SUFFIX_KHR 0x0920 | |
| Returned by clGetPlatformIDs when no platforms are found | |
| CL_PLATFORM_NOT_FOUND_KHR -1001 | |
| Additions to Chapter 4 of the OpenCL 1.0.48 Specification | |
| In section 4.1, replace the description of the return values of | |
| clGetPlatformIDs with: | |
| "clGetPlatformIDs returns CL_SUCCESS if the function is executed | |
| successfully and there are a non zero number of platforms available. | |
| It returns CL_PLATFORM_NOT_FOUND_KHR if zero platforms are | |
| available. It returns CL_INVALID_VALUE if <num_entries> is | |
| equal to zero and <platforms> is not NULL or if both <num_platforms> | |
| and <platforms> are NULL." | |
| In section 4.1, add the following after the description of | |
| clGetPlatforms: | |
| "The list of platforms accessible through the Khronos ICD Loader | |
| can be obtained using the following function | |
| cl_int clIcdGetPlatformIDsKHR( | |
| cl_uint num_entries, | |
| cl_platform_id *platforms, | |
| cl_uint *num_platforms); | |
| <num_entries> is the number of cl_platform_id entries that can be | |
| added to <platforms>. If <platforms> is not NULL, then | |
| <num_entries> must be greater than zero. | |
| <platforms> returns a list of OpenCL platforms available for access | |
| through the Khronos ICD Loader. The cl_platform_id values returned in | |
| <platform> are ICD compatible and can be used to identify a | |
| specific OpenCL platform. If the <platforms> argument is NULL, | |
| then this argument is ignored. The number of OpenCL platforms | |
| returned is the minimum of the value specified by num_entries or | |
| the number of OpenCL platforms available. | |
| <num_platforms> returns the number of OpenCL platforms available. | |
| If <num_platforms> is NULL, then this argument is ignored. | |
| clIcdGetPlatformIDsKHR returns CL_SUCCESS if the function is executed | |
| successfully and there are a non zero number of platforms available. | |
| It returns CL_PLATFORM_NOT_FOUND_KHR if zero platforms are | |
| available. It returns CL_INVALID_VALUE if <num_entries> is | |
| equal to zero and <platforms> is not NULL or if both <num_platforms> | |
| and <platforms> are NULL." | |
| Add the following to table 4.1: | |
| "-------------------------------------------------------------------- | |
| cl_platform_info Return Type Description | |
| ---------------- ----------- ---------------------------- | |
| CL_PLATFORM_ICD_SUFFIX_KHR char[] Then function name suffix | |
| used to identify extension | |
| functions to be directed to | |
| this platform by the ICD | |
| Loader." | |
| Additions to Chapter 9 of the OpenCL 1.0.48 Specification | |
| Add the following paragraph to the end of Section 9.2: | |
| "For functions supported by the ICD Loader, | |
| clGetExtensionFunctionAddress will return the function pointer of | |
| the ICD Loader implementation. For extension functions which the ICD | |
| Loader is unaware of, the function clGetExtensionFunctionAddress | |
| will determine the vendor implementation to return based on the | |
| string passed in. The ICD Loader will return the result from | |
| querying clGetExtensionFunctionAddress on the vendor ICD enumerated | |
| by the ICD Loader whose ICD suffix is a suffix of the function name | |
| being queried. If no such vendor exists or the suffix of the | |
| function is KHR or EXT then clGetExtensionFunctionAddress will | |
| return NULL." | |
| Interactions with other extensions | |
| None. | |
| Issues | |
| 1. Some OpenCL functions do not take an object argument from which | |
| their vendor library may be identified (e.g, clUnloadCompiler), | |
| how will they be handled? | |
| RESOLVED: Such functions will be a NOOP for all calls through the | |
| ICD. | |
| 2. How are OpenCL extension to be handled? | |
| RESOLVED: OpenCL extension functions may be added to the ICD as | |
| soon as they are implemented by any vendor. The suffix mechanism | |
| provides access for vendor extensions which are not yet added to | |
| the ICD. | |
| 3: How will the ICD handle a NULL cl_platform_id? | |
| RESOLVED: The NULL platform is not supported by the ICD. | |
| 4. There exists no mechanism to unload the ICD, should there be | |
| one? | |
| RESOLVED: As there is no standard mechanism for unloading a vendor | |
| implementation, do not add one for the ICD. | |
| Sample Code | |
| The official source for the ICD loader is available on github, here: | |
| https://github.com/KhronosGroup/OpenCL-ICD-Loader | |
| An abbreviated version of the _cl_icd_dispatch structure is | |
| as follows. | |
| struct _cl_icd_dispatch | |
| { | |
| CL_API_ENTRY cl_int (CL_API_CALL *clGetPlatformIDs)( | |
| cl_uint num_entries, | |
| cl_platform_id * platforms, | |
| cl_uint * num_platforms) CL_API_SUFFIX__VERSION_1_0; | |
| CL_API_ENTRY cl_int (CL_API_CALL *clGetPlatformInfo)( | |
| cl_platform_id platform, | |
| cl_platform_info param_name, | |
| size_t param_value_size, | |
| void * param_value, | |
| size_t * param_value_size_ret) CL_API_SUFFIX__VERSION_1_0; | |
| /* ...continues... */ | |
| } | |
| As an example of this mechanism in action, consider the function | |
| clCreateCommandQueue. The implementation of this function in the | |
| ICD Loader is as follows | |
| cl_command_queue clCreateCommandQueue( | |
| cl_context context, | |
| cl_device_id device, | |
| cl_command_queue_properties properties, | |
| cl_int * errcode_ret) | |
| { | |
| return context->dispatch->clCreateCommandQueue( | |
| context, | |
| device, | |
| properties, | |
| errcode_ret); | |
| } | |
| Conformance Tests | |
| A vendor supports cl_khr_icd if conformance may be run successfully | |
| on their platform through the ICD Loader. | |
| Revision History | |
| Version 8, 2017/08/08 (Ben Ashbaugh) - updated to include HKR | |
| as a scanned registry key for Windows, added github link for ICD | |
| loader source code. | |
| Version 7, 2010/03/02 (Jon Leech) - fix typos for | |
| clGetExtensionFunctionAddress (public bug 258), reflow a paragraph | |
| with very long lines. | |
| Version 6, 2010/02/17 (Jon Leech) - remove URLs pointing to | |
| resources available only to Khronos members, since this | |
| was causing confusion to outside readers of the extension | |
| spec. | |
| Version 5, 2009/12/08 (Christopher Cameron) - Clarify language | |
| of ICD Loader versus Vendor ICD, update Linux enumeration to | |
| reflect bug and email discussion. | |
| Version 4, 2009/11/10 (Christopher Cameron) - Fix typos. | |
| Version 3, 2009/11/05 (Christopher Cameron) - update Linux and | |
| Windows enumeration to use directories and registry values. | |
| Change suffix information to come from platform query. Add | |
| error code for clGetPlatformIDs when there are no platforms. | |
| Version 2, 2009/11/02 (Christopher Cameron) - update Linux | |
| enumeration to use INI file format. Some cleanup of sections. | |
| Update on ICD unload function. | |
| Version 1, 2009/09/20 (Christopher Cameron) - initial extension | |
| specification (see also Khronos bug 5391) |